  • Refractometers measure TDS, which baristas use to calculate extraction yield.
  • Most specialty guidelines consider 18% to 22% extraction yield balanced.
  • Sample temperature is the biggest cause of inaccurate refractometer readings.
  • DiFluid’s RS Extract reads samples up to 65°C without cooling.

Extraction shapes almost every aspect of how a coffee tastes. Grind size, brew ratio, water temperature, and contact time affect how much ground coffee extracts into the cup, and small changes to any of them can turn a balanced brew sour or bitter. For most baristas, taste has been the main way to judge whether extraction is on target.

Refractometers offer a more objective reference point. By measuring brew strength, they let baristas calculate extraction yield, the percentage of dry coffee that ends up in the drink. These readings help baristas track recipes, compare brews, and spot changes.

However, a refractometer reading does not automatically lead to better extraction. Poor sample preparation can produce misleading results, and a number alone cannot tell a barista whether a coffee tastes good. As a result, many baristas take a reading and then struggle to decide what to do with it.

You may also like our article on what roasters need to know about analysing coffee colour.

A DiFluid RS coffee refractometer.

Understanding TDS and extraction yield

A refractometer is an optical instrument that measures how much light bends as it passes through a brewed coffee sample. Stronger coffee bends light more, and the device converts this into a total dissolved solids (TDS) percentage, which shows how much of the liquid is dissolved coffee material rather than water.

Filter coffee typically ranges from 1.15% to 1.45% TDS. Espresso is far more concentrated, usually between 8% and 12% TDS.

Baristas then combine the TDS reading with the coffee dose and beverage weight to calculate extraction yield:

Extraction yield (%) = TDS × beverage weight ÷ coffee dose

“TDS tells us how concentrated the coffee is, while extraction yield tells us how much of the coffee was extracted into the cup,” says Shaun Liew, co-founder of Curate Coffee Roasters and ONO Specialty Coffee & Matcha, and a Malaysia Brewers Cup champion.

“For example, if I brew 20g of coffee and end up with 300g of beverage at 1.30% TDS, that gives me an extraction yield of about 19.5%,” he adds.

Most specialty guidelines treat 18% to 22% as balanced. Below 18%, coffee is often under-extracted and sour. Above 22%, it is often over-extracted, bitter and astringent.

TDS and extraction yield describe different aspects of the same cup, so neither tells the full story on its own.

“I don’t look at TDS and extraction as two separate measurements,” Shaun explains. “I use them together to understand what’s happening in the cup. You can have a coffee that is strong but under-extracted, or weak but well-extracted.”

A high TDS with a low extraction yield usually points to a strong but sour brew. By contrast, a low TDS with a high extraction yield often produces a thin, bitter cup. Plotting both figures on a brewing control chart helps baristas decide whether to adjust grind size, brew ratio or contact time.

Even so, the readings cannot judge quality on their own. “That is why sensory evaluation is still important,” Shaun says. “The numbers help explain the cup, but they don’t define whether the cup is good by themselves.”

The screen on a DiFluid RS refractometer.

Measuring extraction accurately

Taking a reliable measurement is harder than many coffee professionals and prosumers expect.

“Temperature-related issues are one of the biggest factors in incorrect measurements across the industry,” says Ben Barnard, the Program Manager at DiFluid, which designs and manufactures tools for specialty coffee professionals.

For this reason, many refractometers require users to cool samples to room temperature before taking a reading. While DiFluid’s R2 samples across a 20°C to 40°C range, the manual specifies that the sample must stabilise to the device’s temperature for accurate testing.

“Getting precise readings with refractometers takes work,” Ben adds. “Even with an advanced tool like the R2, achieving precision means putting effort into your sample preparation.”

Shaun also notes that results can vary between instruments. “Different devices have different accuracy and precision specifications, and the quality of the sample itself can have a significant effect on the reading,” he says. He recommends validating any refractometer against your own workflow before relying on it.

A few habits make measurements more reliable:

  • Filter samples, because undissolved solids distort the result.
  • Zero the device before measuring. DiFluid suggests using distilled water for comparable figures, or your brewing water to isolate what the coffee added.
  • Weigh the dose accurately, since it feeds directly into the extraction yield calculation.
  • Measure the same recipe several times to understand what normal readings look like for your setup.

“This teaches you what your numbers normally look like and helps you understand the relationship between your recipe, your sensory experience and your extraction,” Shaun says.

How refractometer technology is evolving

Refractometers are becoming more common in specialty coffee, but they are not yet standard equipment.

“You see them much more frequently in cafés that are heavily focused on coffee quality, brewing development, education, or competitions,” Shaun says.

He believes many cafés still see refractometers as tools for competitions, roasteries, or highly technical work. “I think the biggest thing that could change that is making the technology easier to understand and easier to use,” he explains.

DiFluid’s new RS Extract addresses two of the main barriers. It reads samples between 4°C and 65°C, so baristas don’t need to wait for coffee to cool, and it eliminates the need for a pipette. It works with both filter coffee and espresso, with espresso samples first passed through a syringe filter.

The device can also pair with a DiFluid scale over Bluetooth to log water, flow rate, and brew time during the pour. Users enter the dose once, and the RS Extract carries it through to the extraction yield. DiFluid’s CoffeeOS app saves each reading alongside the bean, roast profile, and grind setting it belongs to, so baristas can compare brews and spot what changed between them.

“My experience with the RS has been that convenience is a big part of its value,” Shaun says. “For a busy coffee environment, the easier it is to take a measurement, the more likely the team is actually going to use it.

“For me, a good refractometer needs to fit naturally into the way a barista works,” he adds. “If measuring one coffee becomes too complicated or time-consuming, it is less likely to become part of the daily workflow.”

A barista prepares a sample on a coffee refractometer.

Practical applications for using coffee refractometers

For beginners, Shaun’s advice is direct. “Don’t start by chasing a number. Start by learning how to taste,” he says. “First brew coffee, taste it, and form your own opinion about what you like. Then use the refractometer to understand why you are getting that result.”

In his shops, the refractometer is “more a quality-control and training tool than something we need to use for every single cup”.

When his team develops a brew recipe, they taste it first. “If we’re happy with the flavour, we can measure the TDS and extraction to create a reference point,” Shaun explains. “Then, if something changes, perhaps the coffee tastes weaker, more acidic or more bitter, we can measure it and see whether the brewing parameters have shifted.”

The device also supports staff training. “Instead of telling my team, ‘This extraction is too low,’ we can taste the coffee together, measure it, and connect the sensory experience to the number,” he says. “Over time, that helps baristas develop their palate and understand cause and effect.”

Compared with other systems, Shaun views RS Extract through the lens of accessibility. “The more approachable the equipment becomes, the easier it is for cafés to start using data without feeling that coffee measurement has to be overly scientific,” he says. 

A DiFluid RS refractometer next to a scale and a cup.

Refractometers can’t replace a trained palate, but they can help baristas understand why a coffee tastes the way it does. By linking sensory impressions to TDS and extraction yield, teams can make specific, repeatable recipe adjustments rather than relying on guesswork.

As devices become easier to use, with wider temperature ranges and automatic data logging, more cafés and home brewers can build a reliable record of what works. For those starting out, taste first, measure the same recipe several times, and use the data to guide small, deliberate extraction changes.